Skip to main content

V2.1

Minor Versionm

by Rene Weber

Introduction

This guide explains the steps of how to connect HABEL Dokumentenmanagement Software Release Version 2017 with the Silent Brick WORM Archive Version 2.10

    • Requirements Compliance Option is necessary to enable various WORM volume types.

    • Installation and Connectors Installation and electrical connection as well as network connection are to be done as described in the manual

    • Installation Network Adjustments The network settings are to be adjusted as described in the manual Installation

  1. Go to Preferences -> SMB
    • Go to Preferences -> SMB

    • Add a new user matching your HABEL service user

  2. Assign at least one Brick to the Stage Bricks. Brick may be
    • Assign at least one Brick to the Stage Bricks. Brick may be

    • Standard Brick

    • FLASH Brick

    • WORM Brick. Will be partitioned. Size as needed. Default: 1TB

    • Add one or more Bricks to the Archive

    • HABEL will write containers files of a configurable size. Default: 100 MB

    • Using a WORM as Stage can not be reverted!

  3. Choose 'add' under 'Sub Volumes' Tab of your archive
    • Choose 'add' under 'Sub Volumes' Tab of your archive

    • Volume Name: HABEL

    • Volume Type: WORM with Retention ( RW/RO triggered )

    • Retention: As desired. Default: 10 years.

    • Check the checkboxes for

    • Do not archive 0-byte files

    • Do not allow renaming of files

  4. To create a SMB Share click 'Add SMB Share'
    • To create a SMB Share click 'Add SMB Share'

    • Share path: /

    • Share name: HABEL

    • User: As defined in step 1

    • Uncheck the checkboxes

    • Case sensitive

    • Browseable

    • In older HABEL releases ( pre Release 2017 ) HABEL will need a readonly share for clients and a readwrite share for HABEL Dokumentenmanagement

  5. Configure the UNC path in you HABEL Dokumentenmanagement
    • Configure the UNC path in you HABEL Dokumentenmanagement

    • If needed configure retention policy for your archive. Otherwise the default set in Step 3 will be used

Finish Line

Rene Weber

Member since: 10/27/2016

4,530 Reputation

50 Guides authored

Team

FAST_Dozuki_Admins Member of FAST_Dozuki_Admins

8 Members

73 Guides authored

0 Comments

Add Comment

View Statistics:

Past 24 Hours: 0

Past 7 Days: 0

Past 30 Days: 0

All Time: 69

© 2019 FAST LTA | Alle Rechte vorbehalten | Änderungen jederzeit ohne vorherige Ankündigung möglich