Introduction
This manual is for connecting the archival software Gräbert Software + Engineering ArchivPlus Version 6.4.5.
This guide is tested with the Silent Brick WORM Archive Version 2.11
-
-
Requirements Compliance Option is necessary to enable various WORM volume types.
-
Installation and Connectors Installation and electrical connection as well as network connection are to be done as described in the manual Installation
-
Network Adjustments The network settings are to be adjusted as described in the manual Installation
-
-
-
Create an archive including WORM and Stage Brick
-
Create a sub-volume of type WORM with Retention (RWRO triggered).
-
The retention period in years and days must be adopted to the value necessary for the data content being archived
-
Select the option 'Prevent renaming of files'
-
Select the option 'Do not archive 0-byte files'
-
-
-
Create a NFS share for the previously create volume
-
Choose 'Add Client'
-
Set the IP address of your ArchivePlus server as 'Single IPv4 Address'
-
-
-
Follow the Gräbert manual for connecting the archive via NFS
-