Skip to main content

V1.0

Major VersionM

Approved FAST Operations Approval - Major

by Rene Weber

Introduction

This manual is for connecting the archival software Gräbert Software + Engineering ArchivPlus Version 6.4.5.

This guide is tested with the Silent Brick WORM Archive Version 2.11

    • Requirements Compliance Option is necessary to enable various WORM volume types.

    • Installation and Connectors Installation and electrical connection as well as network connection are to be done as described in the manual Installation

    • Network Adjustments The network settings are to be adjusted as described in the manual Installation

  1. Create an archive including WORM and Stage Brick Create a sub-volume of type WORM with Retention (RWRO triggered).
    • Create an archive including WORM and Stage Brick

    • Create a sub-volume of type WORM with Retention (RWRO triggered).

    • The retention period in years and days must be adopted to the value necessary for the data content being archived

    • Select the option 'Prevent renaming of files'

    • Select the option 'Do not archive 0-byte files'

  2. Create a NFS  share for the previously create volume
    • Create a NFS share for the previously create volume

    • Choose 'Add Client'

    • Set the IP address of your ArchivePlus server as 'Single IPv4 Address'

    • Follow the Gräbert manual for connecting the archive via NFS

Finish Line

Rene Weber

Member since: 10/27/2016

4,530 Reputation

50 Guides authored

Team

FAST_Dozuki_Admins Member of FAST_Dozuki_Admins

8 Members

73 Guides authored

0 Comments

Add Comment

View Statistics:

Past 24 Hours: 0

Past 7 Days: 0

Past 30 Days: 0

All Time: 24

© 2019 FAST LTA | Alle Rechte vorbehalten | Änderungen jederzeit ohne vorherige Ankündigung möglich