The system will be unavailable during the update.
-
The user interface of the system can be reached via WebBrowser at https://<System IP>
-
Check which software version is currently installed on the system.
-
If you have software version 2.31 or higher, you can update directly to 2.65
-
-
-
Go to the Software Update Page. There you will find a lot of information describing new and discontinued features
-
-
Scroll down a bit and you will find the download link on the right side of the page.
-
It is not possible to downgrade the system back to an older version.
-
Download the latest software via the download link
-
-
Do not unpack the .tar file. The file is automatically unpacked and checked by the system.
-
Do not rename the downloaded file. The system expects the file to be checked as a .tar file with the original name.
-
-
-
Stop the data storing to the system before the update.
-
Take the archives and volumes offline.
-
Reboot the system via the GUI to ensure that no processes are hanging after a long period of operation. In a replicated system, both systems must be rebooted.
-
Wait until the reboot is complete and the system is accessible again.
-
In case of a replicated system, with primary and secondary system you have to update the secondary system first. When the secondary system is ready, you can start with the primary system.
-
-
-
In case of a replicated system, start now with the secondary system.
-
Go via https://<System IP> to the GUI of the respective system.
-
Click "Service" -> "File Update of Silent Brick System. Click "Browse" and select the relevant update file.
-
When you have selected the correct file, Click "Update".
-
-
-
Depending on software version, used hardware and the number of stored files, the update on individual machines require approx. 30 - 60 minutes for the update.
-
Controllers with connected shelves need up to 2 hours if a firmware update has to be done on the shelf and the inserted bricks !
-
During the update, the system must not be restarted or disconnected from power supply.
-
-
-
Take the archives and volumes online.
-
Wait until all archives and volumes are online again
-
Everything should now be online again.
-
If you see here "Pending validation" the Update ist still running
-
If you only have one system, the update is now complete. If not, carry out the steps just performed on the primary system.
-
-
-
When the Update of the secondary system is finished, start with the primary system.
-
Carry out the steps just performed on the primary system.
-
Check the system. Click "Shelves" and "Bricks" in "Resources".
-
Everything on both systems should be now online again.
-